RETURN TO                                                                                                            Printer Friendly
    HOME                                                                                                                  Version

PROPELLER PUMP NOZZLE AND
SHROUD REPLACEMENT

!WARNING: RISK OF ELECTRIC SHOCK, DISCONNECT POWER PRIOR TO SERVICING
STEP 1  Place the fountain upright with the motor resting on a stable surface.  CAUTION: Do not allow the unit to fall over as damage may occur.

STEP 2  Remove the nozzle by loosening the two hex head screws on both sides of the nozzle.  Rotate the Nozzle counter-clockwise to unlock and lift nozzle upward off the nozzle throat.

STEP 3  Remove the nozzle throat from the motor mount by removing the four hex head machine screws and the prop shroud.

STEP 4 Remove any remains of the original prop shroud and/or debris.

STEP 5  Install the new prop shroud and nozzle assembly in reverse order.  Caution:  Insure flow straightner is installed and that the propeller turns freely.

1-800-821-3177
8100 Paseo
Kansas City, MO  64131
Fax 816-363-2322  sales@airolator.com
Copyright 2007