RETURN TO                                                                                                              Printer Friendly
    HOME                                                                                                                     Version

LEGACY CENTRIFUGAL PUMP NOZZLE OR
WATER PLENUM REPLACEMENT

!WARNING: RISK OF ELECTRIC SHOCK, DISCONNECT POWER PRIOR TO SERVICING
STEP 1  Place the fountain upright with the motor resting on a stable surface.  CAUTION: Do not allow the unit to fall over as damage may occur.

STEP 2  Remove the two 10-24 machine screws located on both sides of the water plenum.

STEP 3  Pull upwards on the nozzle to remove from the water plenum.

STEP 4  Inspect the flow straightner inside the water plenum and remove any debris.

STEP 5  Install new nozzle by aligning holes of nozzle to water plenum.  Push down on nozzle until it stops, secure with two 10-24 machine screws.

STEP 6  To remove the water plenum, remove the four 1/4-20 hex head cap screws from the flange of the water plenum.  Remove the plenum and gasket from the pump lid.  Remove any debris that is present.

STEP 7  Install new gasket and water plenum with the four 1/4-20 hex head cap screws.

1-800-821-3177
8100 Paseo
Kansas City, MO  64131
Fax 816-363-2322  sales@airolator.com
Copyright 2007