| STEP 1 Place the
fountain upright with the motor resting on a stable surface.
CAUTION: Do not allow the unit to fall over as damage may occur. STEP 2 Remove the two 10-24 machine screws located on both sides of the water plenum. STEP 3 Pull upwards on the nozzle to remove from the water plenum. STEP 4 Inspect the flow straightner inside the water plenum and remove any debris. STEP 5 Install new nozzle by aligning holes of nozzle to water plenum. Push down on nozzle until it stops, secure with two 10-24 machine screws. STEP 6 To remove the water plenum, remove the four 1/4-20 hex head cap screws from the flange of the water plenum. Remove the plenum and gasket from the pump lid. Remove any debris that is present. STEP 7 Install new gasket and water plenum with the four 1/4-20 hex head cap screws. |
|